条件に該当する製品289件
-
A429-V2
Abaco Systems (旧GE Intelligent Platforms) 1553/ARINC VMEbus 防衛 生産中止品(EOL)・VME form factor ARINC429 ・Sink data can be filtered and received in a current value table, local and/or global monitor buffers ・IRIG available. Also available with a Special Configuration that routes the I/O to P2 connector. ・Source lists can be added to any channel
-
800-202
Abaco Systems (旧GE Intelligent Platforms) 通信I/O VMEbus ロボット 半導体製造機 生産中止品(EOL)VME64 Bus Adapter with DMA ・Power requirements: 2.5A at 5V ・Meets IEEE 1014C specifications ・Operating temperature: 0 to +60 degrees C ・Storage temperature: -40 to +85 degrees C ・Humidity: 5% to 90%, non-condensing
-
VME-3113A
Abaco Systems (旧GE Intelligent Platforms) アナログI/O VMEbus 鉄道/交通 生産中止品(EOL)・Powers up in autoscanning mode-no software initialization required ・Continually digitizes all input channels and stores the results in dedicated channel dual-port registers (autoscanning mode) ・64 differential or single-ended inputs ・Supports real-time and off-line Built-in-Test
-
VME-3123
Abaco Systems (旧GE Intelligent Platforms) アナログI/O VMEbus 物理 天体 生産中止品(EOL)・Built-in-Test ・internal references applied to channel inputs: all active devices tested ・Simultaneous sample-and-hold inputs ・High throughput with channel pairing ・Digital calibration: no channel trimmers ・16-bit A/D converters: one per channel ・or 16 active channels ・16 differential analog input channels ・16 Channels with Simultaneous Sample-and-Hold Inputs ・16-bit High Throughput Analog Input Board
-
VME-3122
Abaco Systems (旧GE Intelligent Platforms) アナログI/O VMEbus 物理 天体 生産中止品(EOL)・Continually digitizes selected input channels and stores the results ・Program-selectable scanning of 1, 8, 16, 32, 48, or 64 channels ・Software-selectable conversion rate (100 kHz maximum) ・16-bit A/D conversion ・64 differential or single-ended inputs ・Three trigger modes ・Three scan modes
-
VME-3125
Abaco Systems (旧GE Intelligent Platforms) パラレル VMEbus 鉄道/交通 生産中止品(EOL)・Applications: Instrumentation in 3U Form Factor, Isolated Analog Inputs, Isolated Transducer Inputs, Ground Loop Elimination, Data Acquisition Systems, Medium-Rate Voltage Monitoring, Process Monitoring, Temperature Monitoring ・1,000 V analog GND/digital GND isolator ・Low pass input filters: 50 kHz, optional 40 Hz ・Pull-down resistors prevent floating inputs ・offset binary or two's complement ・Overvoltage protected inputs ・Selectable data coding ・Input connector compatible with both discrete wire and ribbon cables ・Jumper-programmable gains of x1, x10, x100 ・Selectable A/D ranges of +/-5 V, +/-10 V, 0 to +10 V ・Supports real-time Built-in-Test ・40 kHz aggregate conversion rate ・Input ranges from +/-50 mV to +/-10 V ・Isolated channel-to-bus ・common channel-to-channel ・Autoscanning ・continuously digitizes inputs and stores results in dual-ported data registers ・32 single-ended or 16 differential inputs ・Operating Systems: Windows NT, Linux, VxWorks, QNX
-
VME-3126
Abaco Systems (旧GE Intelligent Platforms) パラレル VMEbus 鉄道/交通 生産中止品(EOL)・8 or 16 isolated input channels with active guards ・16-bit data ・1,500 VDC (1,000 VAC) isolation, input-to-input and input-to-VMEbus ・Digitizer per channel ・Input ranges of ±50 mV to ±10 V, software-selectable on channel-by-channel basis ・Software-controlled bandwidth, 0.05 to 26 Hz (6 pole low pass filters implemented with internal DSP) ・DSP-based offset and gain correction in real-time ・DSP supported E2PROM stores calibration coefficients (no trimpots) ・Conversion rate of 100 SPS (samples per second) per channel ・RTD excitation under software control (200 mA/400 mA per channel) ・Open transducer detection under software control ・Supported by GE Intelligent Platforms Embedded System's I/O controllers ・Optional current termination resistors ・Optional increased input range
-
VME-3418
Abaco Systems (旧GE Intelligent Platforms) アナログI/O VMEbus 鉄道/交通 生産中止品(EOL)・Constant current or constant voltage bridge excitation ・Open sensor detection ・Individual sensor excitation for each channel ・Four-, three-, or two-wire resistance temperature detectors (RTDs); prescaled RTD ranges available ・Full, half, or quarter strain gauge bridges, with on-board bridge completion ・Isolated to 1,000 VDC or 700 VRMS in two groups of four channels ・8 isolated strain gauge and RTD signal conditioning channels ・Input ranges selectable from ± 10 mV to ± 10 V ・Optional low pass input filters; 4, 40, or 400 Hz ・Buffered high-level analog outputs
-
VME-4105
Abaco Systems (旧GE Intelligent Platforms) アナログI/O VMEbus 物理 天体 生産中止品(EOL)・2- or 4-quadrant multiplier option ・0 to -10 V option ・+/-10 V outputs ・8-channel analog output ・12-bit DAC per channel ・Jumper-selectable P2 or front panel outputs
-
VME-4900
Abaco Systems (旧GE Intelligent Platforms) アナログI/O VMEbus 物理 天体 生産中止品(EOL)・Model VME-4900-218R is directly compatible with high power synchro booster amplifiers ・1.5, 4.5, and 5.0 VA outputs ・Nonprivileged or supervisory short I/O ・Compatible with GE Embedded Systems Intelligent I/O Controller product line ・Supports real-time and off-line fault detection and isolation ・AMP D-type connector (no. 206584-1) for front panel field connection ・Front panel fail LED ・Internal transformers ・3- or 4-wire output for driving synchros or resolvers, respectively ・14-bit converter with an overall accuracy of ±4 arc minutes ・Model VME-4905 is also available with 5.0 VA outputs