条件に該当する製品297件
-
UTC003
VadaTech HUB AdvancedMC 鉄道/交通・Single-width, full-height module per AMC.0 ・Single-width, full-height module per AMC.0 ・400MHz RISC CPU with 64MB DDR for MCMC (MicroTCA Carrier Management Controller) and Shelf Manager ・400MHz RISC CPU with 64MB DDR for MCMC (MicroTCA Carrier Management Controller) and Shelf Manager ・HPM.1 compliant ・Linux 2.6 embedded OS ・UTC003 can run as an IPMI protocol analyzer to monitor all the I2C Busses ・IPMI 2.0 compliant ・Redundant boot system to ensure fail-safe upgrades ・HPM.1 compliant ・Fail-over with dual UTC003 in system ・UTC003 can run as an IPMI protocol analyzer to monitor all the I2C Busses ・GbE to each AMC (layer two managed) ・Redundant boot system to ensure fail-safe upgrades ・SAS/SATA to each AMC ・Fail-over with dual UTC003 in system ・Non-blocking PCIe x4 Gen 2 to each AMC slot with option for SRIO or 10GbE (layer three managed) ・GbE to each AMC (layer two managed) ・Fabric clock with Spread Spectrum capability ・SAS/SATA to each AMC ・Linux 2.6 embedded OS ・Non-blocking PCIe x4 Gen 2 to each AMC slot with option for SRIO or 10GbE (layer three managed) ・IPMI 2.0 compliant ・Fabric clock with Spread Spectrum capability
-
UTC008
VadaTech TOOL/開発環境 AdvancedMC 試験 環境・JTAG Switch Module (JSM) per μTCA specification ・Provides Transparent Communications between the Arbitrated Master and a selected Secondary Port ・Autodetection of Port Presence ・Three Arbitrated Master ports ・Configuration Mode Uses IEEE 1149.1 TAP controller ・Operation up to 50MHz ・LED for Activity, Master Grant, Secondary port selection ・Mates directory to the Chassis that have the JSM connector ・Support for 12 AMC, 2 MCH, 4 Power Module, 2 Cooling units and Front/Rear (21 Ports) ・Standard half-height AMC front panel ・Operations via Front/Back, or the two MCH
-
UTC007
VadaTech TOOL/開発環境 AdvancedMC 試験 環境・JTAG Switch Module (JSM) per μTCA specification ・Provides Transparent Communications between the Arbitrated Master and a selected Secondary Port ・Mates directory to the Chassis that have the JSM connector ・Support for 12 AMC, 2 MCH, 4 Power Module, 2 Cooling units and Front/Rear (21 Ports) ・Operations via Front/Back, or the two MCH ・Autodetection of Port Presence ・Three Arbitrated Master ports ・Configuration Mode Uses IEEE 1149.1 TAP controller ・Operation up to 50MHz ・LED for Activity, Master Grant, Secondary port selection
-
UTC011
VadaTech 電源 AdvancedMC 試験 環境・Single-width, full-height module per AMC.0 ・Dual 10 to 36 VDC input for 241W option and 18 to 36 VDC input for 460W option ・Dual IPMI bus ・32-bit RISC processor ・Two banks of 256K flash for redundancy ・Field upgradable ・IPMI 2.0 compliant ・HPM.1 compliant ・Without the presence of an MCH the modules can be turned on ・Menu driven software for ease of configuration ・Current measure for each module ・External as well as internal WDT ・Support for power module redundancy
-
UTC010
VadaTech 電源 AdvancedMC 試験 環境・Single-width, full-height module per AMC.0 ・Dual -36VDC to -75VDC input ・Blue, Red, Amber and Green LEDs ・Field upgradable ・IPMI 2.0 compliant ・HPM.1 compliant ・792W (available in 396W) ・Hot swappable ・Support for power module redundancy ・Dual IPMI bus ・32-bit RISC processor ・Two banks of 256K flash for redundancy
-
UTC013
VadaTech 電源 AdvancedMC 試験 環境・Double-width, full-height module per AMC.0 ・Dual -36VDC to -75VDC input ・HPM.1 compliant ・Without the presence of an MCH the modules can be turned on ・Menu driven software for ease of configuration ・Current measure for each module ・External as well as internal WDT ・Available in μTCA.3 Conduction Cool ・792W (available in 396W) ・Hot swappable ・Support for power module redundancy ・Dual IPMI bus ・32-bit RISC processor ・Two banks of 256K flash for redundancy ・Blue, Red, Amber and Green LEDs ・Field upgradable ・IPMI 2.0 compliant
-
UTC012
VadaTech 電源 AdvancedMC 試験 環境・Single-width, full-height module per AMC.0 ・Dual 10 to 36 VDC input for 241W option and 18 to 36 VDC input for 460W option ・Two banks of 256K flash for redundancy ・Field upgradable ・IPMI 2.0 compliant ・HPM.1 compliant ・Without the presence of an MCH the modules can be turned on ・Menu driven software for ease of configuration ・Current measure for each module ・External as well as internal WDT ・Support for power module redundancy ・Dual IPMI bus ・32-bit RISC processor
-
UTC018
VadaTech 電源 AdvancedMC 防衛・Double-width, 12HP height module ・Universal AC input (85 to 265V), 1000W ・Hot swappable ・Two banks of 256K flash for redundancy ・Dual IPMI bus ・32–bit RISC processor ・Blue, red, amber and red LEDs ・IPMI 2.0 and HPM.1 compliant ・Menu driven software ・Current sensor per slot ・Provides power up to 12 AMCs, 2 MCHs and Cooling Units ・Very low ripple voltage on +12 V
-
UTC017
VadaTech 電源 AdvancedMC 防衛・Double-width, full-height module per AMC.0 ・Double-width, full-height module per AMC.0 ・Universal AC input (85-265 VAC) ・Universal AC input (85-265 VAC) ・Support for power module redundancy ・32-bit RISC processor ・Dual IPMI bus ・Two banks of 256K flash for redundancy ・32-bit RISC processor ・Blue, Red, Amber and Green LEDs ・Two banks of 256K flash for redundancy ・Field upgradable ・Blue, Red, Amber and Green LEDs ・IPMI 2.0 compliant ・Field upgradable ・HPM.1 compliant ・IPMI 2.0 compliant ・Without the presence of an MCH the modules can be turned on ・HPM.1 compliant ・Menu driven software for ease of configuration ・Without the presence of an MCH the modules can be turned on ・Current measure for each module ・Menu driven software for ease of configuration ・Available in μTCA.1, μTCA.2 and μTCA.3 ・Current measure for each module ・500W with very low ripple voltage on the +12V ・Available in μTCA.1, μTCA.2 and μTCA.3 ・Hot swappable ・500W with very low ripple voltage on the +12V ・Support for power module redundancy ・Hot swappable ・Dual IPMI bus
-
UTC020
VadaTech 電源 AdvancedMC 鉄道/交通・Single-width, full-height module per AMC.0 ・Dual -36VDC to -75VDC input ・Hot swappable ・Support for power module redundancy ・Dual IPMI bus ・32-bit RISC processor ・Two banks of 256K flash for redundancy ・Blue, Red, Amber and Green LEDs ・Field upgradable ・IPMI 2.0 compliant ・HPM.1 compliant ・Without the presence of an MCH the modules can be turned on ・Menu driven software for ease of configuration ・Current measure for each module ・External as well as internal WDT ・Available in uTCA.3 Conduction Cool ・936W (available in 468W)