条件に該当する製品191件
-
Parvus DuraNET 20-10
Curtiss-Wright スイッチ BOX 防衛Small Form Factor Ethernet Switch ・20-Ports of 10/100/1000Mbps Gigabit Ethernet in Size, Weight & Power (SWaP) Optimized Chassis: Only 4 lbs. Weight, < 3” Height, 112 Cubic Inches in Size, < 25 Watts Max Power ・Carrier Ethernet Switch Engine with Embedded 32-Bit Management Processor ・Robust Layer 2 Switching and Network Management Software Support ・Extremely Low Power Design: Energy Efficient Ethernet (IEEE-802.3az) Support with Low-Power PHYs and Smart Cable Reach Technology Management ・Carrier Ethernet Services Software Deliver Rich Layer-2 Switch Features, Layer 3-Aware Packet Processing, Service Classification and Traffic Policing; IEEE- 1588 Precision Timing Protocol and Hardware Accurate Timestamping ・L2 Switch Management: 10/100/1000 Mbps Gigabit Ethernet Connectivity, IPv4 / IPv6 Multicast, VLAN, QoS/CoS Traffic Prioritization, Multiple/Rapid Spanning Tree, Link Aggregation, IEEE-1588 Precision Timing Protocol ・Layer 3 IPv4 / IPv6 Unicast Static IP Routing to Attached WAN / Radio Ports ・SNMPv3, HTTP Server, Web GUI, RS-232 Console CLI, Port Monitoring, RMON, Syslog, Network Access Server (NAS), 802.1X Authentication, IGMP Snooping, Access Control Lists (ACLs), Zeroization, Built-in-Test (BIT) Diagnostics Rugged MIL-STD-Design ・Designed to Meet Harsh MIL-STD-810G & DO-160 Conditions (Temp, Shock, Vibration, Humidity, Altitude, Dust/Water Ingress) ・Designed to Meet DO-160 & MIL-STD-461F EMI/EMC (Conducted & Radiated Emissions & Susceptibility) and MIL-STD-1275 & 704 Power Input and Transient Protections ・-40 to +71C Fanless Extended Temp Operation with No Moving Parts ・Corrosion-Resistant, Aluminum Chassis Sealed Against Water, Dust, EMI ・Circular MIL-DTL-38999 Connectors for Reliable Network Connections ・Filtered, Transient-Protected Power Supply for Aircraft and Vehicle Use ・Data Zeroization Support to Sanitize Configuration Information
-
VME-680 Ethernet Switch/Router
Curtiss-Wright スイッチ/ルーター VMEbus 防衛 生産中止品(EOL)・Dual IPv4/v6, Fully managed, intelligent multi-layer gigabit Ethernet switch with a 6U VME64 form factor. ・Up to twenty four 10/100/1000 Mbps non-blocking auto-negotiating ports operating at wire-speed ・Flexible port combinations (4 Gigabit Ethernet (front), 4 Fiber Optic (to front) or 4 Fast Ethernet (to rear) ・Dual Broadcom BCM5690 managed switch devices with a Motorola MPC8245 control and management processor ・64 Mbyte SDRAM with ECC, 4 Mbyte boot flash, 32 Mbyte configuration flash ・Out of band backplane management and debug port (10/100 Ethernet), JTAG support, and serial interface ・Fully integrated Layer 2 switching, Layer 3 routing, Quality of Service (QoS), IP multicast, security and network management ・Intuitive command line interface, web interface and SNMP interface for easy configuration and network management ・Air-cooled and conduction-cooled versions available
-
VME-682 Ethernet Switch/Router
Curtiss-Wright スイッチ/ルーター VMEbus 防衛 生産中止品(EOL)・Fully managed, intelligent multi-layer (layer2/3) gigabit Ethernet switch in a 6U VME form factor ・Complete range of convection and conduction cooled formats (IEEE 1101.1 and IEEE 1102.1) with shock and vibration support ・Up to 24 x 1GbE (10/100/1000 Mbps) auto-negotiating copper interfaces (4 of the ports can be optical) ・Up to 2 x 10GbE (10 Gbps) XAUI interfaces ・Transient voltage suppressors on each GbE port to protect from electrostatic discharge (ESD), cable discharge events (CDE), lightening and other induced voltage surges ・Wirespeed performance for all packet sizes at layer 2 or layer 3 including jumbo packets ・EIA232 out of band serial management and 10/100 debug port ・Ideal for architecting IPv4, IPv4/v6, or pure IPv6 transformational network architecture with support for intelligent routing ・Flexible network management, monitoring, and configuration capability via CLI, Telnet, Web, and SNMP interfaces ・Supports latest switching/routing features for layer 2 switching; layer 2 multicasting; VLANs; Spanning Tree (Rapid and Multiple); link aggregation; port mirroring; CoS/QoS features; layer 3 IPv4/v6 routing; tunneling; IP Multicasting ・Ubiquitous security including Secure Memory Erase; user authentication; port based security; protocol-based security; broadcast storm control; secure sockets layer (SSL); secure shell (SSH); stateless firewall capability; flexible Access Control Lists (ACLs); Network Address Translation (NAT) ・Extensive Built in Test (BIT) capability including Power up BIT, Initiated BIT and Continuous BIT
-
VXS I/O Controller
Curtiss-Wright HUB VMEbus 防衛 生産中止品(EOL)・Two x4 VXS links to backplane ・Dual 4Gbit/s Fibre Channel ports ・Dual XMC/PMC sites with x8 PCI Express® (PCIe) or independent 64-bit 133MHz PCI-X ・667MHz AMCC PowerPC™ 440SP processor ・512MB high-speed streaming memory ・Xilinx® Virtex®-5 SX95T (standard) or LX155T ・512MB DDR2 SDRAM (4 banks of 128MB) ・Air- or conduction-cooled rugged versions ・Board Support Package (BSP) for VxWorks®
-
Parvus DuraMAR 31-5915
Curtiss-Wright ルーター BOX 防衛・Cisco Technology ・Ruggedized Cisco 5915 Router with Enterprise IOS Software for Robust Security, Management, QoS, VLAN, IPv4 / IPv6 Routing, IP Mobility ・5 Ethernet Ports (3x 10/100 Switched, 2x 10/100 Routed) ・Integrated Services Router (ISR) Features Support Concurrent Data, Video, and Voice Services, Firewall and Hardware AES Encryption Acceleration ・Modular, Open Architecture Rugged COTS PC104 Hardware Design ・Mobile Networking ・Extensive Routing Protocols, IPv4 / IPv6 Support, Mobile Ad Hoc Networking, Radio Aware Routing, Mobile IP, and Management Capabilities ・Sophisticated Networking Capabilities, including Quality of Service (QoS) to Ensure the Most Important Data Gets Through When Links are Degraded ・Security to Protect the Network and the Data Transmitted Over the Network ・Remote Voice Services with Cisco Unified Communications Manager Express ・Streaming Multicast Video Support ・Self-Forming, Immediate Connection with No Preconfiguration of Peers Required, Eliminating the Need for Connectivity to the Centralized Network ・Rugged Mechanical Design ・Water Tight, Sealed Metal Enclosure ・Anodized Coated Aluminum Chassis for Durability ・Integrated Heat sinking for Fanless Cooling ・-40 to +71C Fanless Extended Temp Operation with No Moving Parts ・Rugged RJ-45 or M12 Connectors for Anti-Shock and Vibe Protection ・IP67 Ingress Protected from Sand, Dust, Moisture, Immersion ・Bulkhead Mountable Enclosure with Integrated Flanges ・Inherently Rugged Open Architecture PC-104 Based ・Reliable Power ・Robust Vehicle-Grade Wide Input DC Power Supply ・Voltage/Surge Protection and EMI Filtering
-
Parvus DuraNET 1268
Curtiss-Wright スイッチ BOX 防衛Ports ・Ethernet - 10x 10/100/1000Mbps Gigabit Ethernet Switch Ports ・Management - 1x RS232 and 10/100 Ethernet Management/Console Ports for Configuration Management ・Interfaces: MIL-DTL-38999 Copper Ethernet on Front Panel and Optional Tactical Fiber Optic Media Assembly (TFOCA II) on Rear Rugged Small Form Factor ・Only ~5 lbs Weight, < 4” Height; -40 to +71C Fanless Extended Temp ・Passively Cooled Aluminum Chassis with No Moving Parts ・Ingress Protection from Sand, Dust, Water (IP67-like) ・Conformal Coated Boards for Humidity and Tin-Whisker Mitigation MIL-STD + DO-160 Qualified ・Environmental: Tested to MIL-STD-810G (Shock, Vibration, Temp, Humidity, Altitude, Immersion), DO-160G (Temperature, Altitude) ・EMI: MIL-STD-461F (Radiated & Conducted Emissions and Susceptibility) ・Power: Filtered, Transient-Protected Power Supply for MIL-STD-704F Aircraft / MIL-STD-1275D Vehicle Use Management ・Unmanaged or Lightly Managed Switch Configurations ・Link Speed, Duplex Mode, Flow Control on Per-Port Basis; Port Monitoring ・RS-232 Console w/ Command Line Interface (CLI) ・Out-of-Band 10/100 Ethernet Port, Web Browser GUI ・Telnet Server (for Remote CLI Management over Ethernet) VLAN/QoS ・Port-Based and 802.1Q Tagged Virtual Local Area Networks (VLAN) ・Class of Service (CoS) / Quality of Service (QoS) Traffic Prioritization; Four Traffic Class Queues; Priority Determined by Port, 802.1p Tagged Frames, IPv4 TOS/Diff-Serv, IPv6 TC Redundancy/Fault Tolerance: Spanning Tree Protocol (STP); Rapid Spanning Tree Protocol (RSTP) Declassification:
-
SwitchBox SMS-652
Curtiss-Wright スイッチ BOX 防衛SWaP-C Optimized Rugged Network Switch ・Extremely small footprint and under 5 pounds weight ・15 Watts typical power 16-port Gigabit Ethernet switch ・Non-blocking architecture supports tri-speed operation (10/100/1000Mbps) with auto-negotiation and auto-MDIX ・Full support for IPv4 and IPv6 networks ・Port, MAC, and protocol-based VLANs ・Spanning Tree support (STP, RSTP, MSTP) ・Multicast support (IGMP/MLD snooping) ・Quality of Service (QoS) ・Support for jumbo frames up to 9KB ・Link aggregation, Port mirroring ・Static routing is also supported for IP routing to attached WAN/radio ports ・Energy Efficient Ethernet (EEE) per 802.3az with built-in cable diagnostics ・Powerful in-band (HTTP/Telnet/SNMP) and out-of-band (RS-232) switch configuration and management Designed for Rugged Commercial, Industrial, and Military Applications ・Natural convection design supports extended operation from -40°C to +75°C operation ・24/28V DC power compliant to MIL-STD-1275 for ground applications, MIL-STD-704 for airborne applications, and Def Stan 61-5 for UK applications
-
SWI-22-10 PCI104 Gigabit Ethernet Switch
Curtiss-Wright スイッチ マザーボード 3.5インチボード 防衛High Port Density • Up to 20 Ports of Gigabit Ethernet Switch Ports in Single-Slot PCI/104-Express Form Factor (3.6”x3.8”) Card; Eight (8) Port Option Roadmapped Rugged Design • -40/+85C Extended Temp, Vibration Tolerant Connectors for Cableless/Cabled Network Connections, Staked & Underfilled Components Carrier Grade • Carrier Ethernet (CE) Switch Engine with Embedded 32-Bit Management Processor • CE Services Software Deliver Rich Layer-2 Switch Features, Layer 3-Aware Packet Processing, Service Classification and Traffic Policing; IEEE-1588 Precision Timing Protocol and Hardware Accurate Timestamping Layer 2 Switching • 10/100/1000 Mbps Gigabit Ethernet Connectivity, IPv4 / IPv6 Multicast, VLAN, QoS / CoS Traffic Prioritization, Multiple/Rapid Spanning Tree, Link Aggregation, IEEE-1588 Sync Management • SNMPv3, HTTP Server, Web GUI, RS-232 Console CLI, Port Monitoring, RMON, Syslog, Network Access Server (NAS), 802.1X Authentication, IGMP Snooping, Access Control Lists (ACLs), Zeroization Low Power • Energy Efficient Ethernet (IEEE-802.3az) Support with Low-Power PHYs and Smart Cable Reach Technology for Extremely Low Power Consumption Bus or External Powering • Can be Powered via PCI-104 (PCI) bus, PCIe104 (PCI Express) bus or Auxiliary Power Connector for Standalone Operation Integration Flexibility • Two Connector (Harwin, Molex) Options to Support Either Hand Crimping CAT5e Cabling or Board-to-Board (Cableless) Interface for Ethernet Ports Layer 3 Routing • Layer 3 IPv4 / IPv6 Unicast Static Routing Support for IP Routing to Attached WAN / Radio Ports
-
Telum NPA-5854
Abaco Systems (旧GE Intelligent Platforms) スイッチ AdvancedMC 通信・ キャリア 生産中止品(EOL)・Designed for NEBS compliance ・IPMI v1.5 compliant ・Software support available for Debian Linux, embedded boot loader and POST diagnostics ・AMC.0 Management Module Controller (MMC) ・2 ports of Gigabit Ethernet to AMC ports 0 & 1 ・Optional mapping of AMC port 10 to port 0 and port 11 to port 1 ・4 ports of Gigabit Ethernet to AMC connector ports 8-11 ・4 front panel access ports of Gigabit Ethernet, copper or fiber SFP ports ・64MB RLDRAM optional ・Up to 2 GB of high-speed DDR2 packet memory ・Supports Cavium OCTEON plus CN5850-SCP
-
UTC006 – MicroTCA Carrier Hub (MCH), Double Module, PCIe Gen 3 Expansion
VadaTech HUB AdvancedMC 物理 天体・Double module, full size per AMC.0 and MTCA.4 ・Quad ports for PCIe Gen 3 expansion (x4, x8, or x16) ・Unified 1GHz quad-core CPU for MCMC (MicroTCA Carrier Management Controller), Shelf Manager, Clocking, and Fabric management ・Automatic fail-over with redundant UTC006s ・1GbE base switch with dual 100/1000/10G uplink ・Full Layer 2 or 3 managed Ethernet switch ・PLL synthesizer for generating any clock frequency disciplined to GPS/SyncE/IEEE1588 ・IPMI 2.0 compliant ・HPM.1 compliant